When the lights go out, people need to know exactly where the door is — and that is the whole job of the TL-RMES-11-WL from TUROLIGHT. This is the pictogram "Running Man" LED exit sign, single face, in a white housing, built and listed for wet location installations. Whether you call it a running man sign, an emergency exit sign, an illuminated exit sign or simply an LED sign, it is the internationally recognized symbol that replaced the old word-based "EXIT" panels across Canada, and it works without translation for everyone in the building.

Inside the injection-molded thermoplastic housing, super bright SMD LED light sources glow at 6500K for a crisp, unmistakable green pictogram, while drawing only 4.2W. It accepts 120/347VAC input voltage, so it drops into residential panels and commercial 347V systems alike. The unit is self-powered with a Ni-Cd battery backup for 2 hours, and a built-in test switch plus charge indicator light let you verify readiness in seconds. It is UL-924 listed for Wet Location, carries a 2-year limited warranty, and operates from -20˚C to +40˚C. Dimensions are 13.94" × 9.13" × 2.99" (L×W×H), with universal wall, ceiling or side mounting.

That -20˚C rating matters in this country: parking garages, loading docks, covered exterior doorways, unheated warehouses, car washes, arenas, pool and spa rooms, walk-in coolers and stairwells open to the weather are exactly where a standard dry-location sign fails. Contractors like it for the three mounting orientations — one SKU covers the corridor, the doorway and the ceiling drop. Homeowners finishing a basement apartment, a duplex or a rental suite use it to meet egress requirements above the exit door. Order the "Running Man" wet location sign today and check one more inspection item off your list.

178.97$


Supplier availability: In stock (+100)

Built for damp, cold and demanding spots
The housing of the TL-RMES-11-WL is injection-molded thermoplastic in a clean white finish, a material that shrugs off humidity, condensation and the salty, dusty air of a garage far better than a painted steel box. The single face design puts the pictogram on one side, which is what you want above a door or at the end of a corridor where traffic arrives from a single direction. TUROLIGHT rates the unit for an operating temperature range of -20˚C ~ +40˚C, so it stays reliable in an unheated dock, a covered entrance or a refrigerated space.

Light quality you can see through smoke and panic
Legibility is everything on an emergency sign. This model uses super bright SMD LED sources at 6500K, a cool daylight tone that makes the green running man pop against a dark or smoke-filled corridor and stay readable from a distance. Because the light engine is LED rather than incandescent, the sign sips only 4.2W while it is energized, which keeps the load on your emergency circuit low and lets the battery do more work when it is needed.

Self-powered, tested in seconds
The unit is self powered: a Ni-Cd battery inside provides 2 hours of backup when normal power drops, with no remote head wiring or central inverter required. A test switch lets maintenance staff simulate a power failure on the spot, and the charge indicator light confirms at a glance that the battery is charging. Input is 120/347VAC, a dual rating that means the same sign serves a house, a strip mall on 120V and an industrial or institutional building running 347V — very handy when you are stocking one part number for a multi-building job.

Technical specifications
SKU / Model: TL-RMES-11-WL
Ordering code: 3461222
Brand: TUROLIGHT
Type: "Running Man" LED emergency sign, single face, white housing
Wattage: 4.2W
Input voltage: 120/347V
CCT: 6500K
Mounting: wall, ceiling, side (universal)
Remote capable: No
Self powered battery: Yes (2 hrs), Ni-Cd
Wet location: Yes
Listing: UL-924 listed for Wet Location
Dimensions (L×W×H): 13.94" × 9.13" × 2.99"
Operating temperature: -20˚C ~ +40˚C
Warranty: 2-year limited

Where to install it, and the paperwork
Think of every door your building code calls an exit and every path leading to it: underground parking levels, exterior vestibules and canopies, warehouse and loading dock doors, arenas and community centres, car washes, breweries and commercial kitchens where wash-down and steam are daily facts, plus stairwells and service corridors. Because it accepts universal wall, ceiling or side mounting, the electrician chooses the orientation on site instead of ordering a second version — a real time saver on retrofits where the junction box is already in place. Full details, the dimensional drawing and the ordering table are in the TL-RMES-11-WL spec sheet available in the Documentation tab of this page; keep a copy with your inspection file, along with a note of the monthly test switch check.