Box covers and plates close an electrical box safely, bring a device flush with the finished wall or prepare an opening for a specific light. This category groups blank metallic covers for 4" and 4 11/16" square boxes and for octagonal boxes, raised covers for 1 and 2 gang devices, blank covers for utility boxes, a J-box cover plate for LED strip installations and concrete pour mounting boxes with top plates for in-concrete LED lights. The ARANI covers make up most of the range, alongside TUROLIGHT and LUMENSTARLED accessories.
The page is written for electricians, contractors and homeowners who need to finish a rough-in properly. Whether you are closing an unused junction, mounting a receptacle on a square box in a garage or preparing a driveway light before a concrete pour, the right cover avoids gaps, loose devices and failed inspections. The product sheets for the ARANI covers list cUL or CSA approval.
A blank cover closes a box that holds only splices. The 52C1 is a blank metallic cover for 4" boxes, and the 72C1 fits 4 11/16" boxes when you need more room. For octagonal ceiling boxes, the 54C1 octagonal metallic blank cover is the standard closure. The 52C6 and the 54C6 add a 1/2" centre knockout, so the same cover can stay solid or accept a cable or conduit fitting. The 11C4 and 20C4 are blank covers for 1110 and 2020 boxes.
A raised cover, sometimes called a mud ring or plaster ring, adapts a square box to one or two devices and brings the mounting plane forward to the finished surface. The 52C13 1 gang 4" cover with 1/2" raise suits standard drywall, and the 52C15 1 gang 4" cover with 7/8" raise handles thicker finishes. The 72C13 does the same job on a 4 11/16" box with a 1/2" raise. For two devices, the 52C17 is a 2 gang 4" cover with 1/2" raise, and the 8371 2 gang 4" cover with 3/8" raise for 2 duplex receptacles is ready for two standard outlets.
The PRO-EC strip J-box cover plate in white closes the junction box at the point where household wiring meets an LED strip run and its driver. It keeps the connection enclosed and gives a clean finish where the strip leaves the box.
The RD32, RD33 and RD34 concrete pour mounting boxes with top plates are installed in the formwork before the pour. They reserve the exact cavity for the matching in-concrete LED light and keep slurry out while the concrete is poured, vibrated and finished. The RD33 concrete pour mounting box and top plate is an accessory: the light itself is a separate product.
| Model | Box format | Openings | Raise |
|---|---|---|---|
| 52C1 | 4" square | Blank | Flat |
| 52C6 | 4" square | 1/2" centre knockout | Flat |
| 52C13 | 4" square | 1 gang | 1/2" |
| 52C15 | 4" square | 1 gang | 7/8" |
| 52C17 | 4" square | 2 gang | 1/2" |
| 8371 | 4" square | 2 duplex | 3/8" |
| 72C1 | 4 11/16" square | Blank | Flat |
| 72C13 | 4 11/16" square | 1 gang | 1/2" |
| 54C1 / 54C6 | Octagonal | Blank / 1/2" knockout | Flat |
Start with the box. A cover must match the box format exactly: 4" square, 4 11/16" square, octagonal or a utility box such as the 1110 or 2020 sizes. A 4 11/16" box gives more wiring room, which helps when several cables meet, but it needs its own 72-series cover.
Next, decide what goes on the box. Splices only: a blank cover. One switch or receptacle: a 1 gang raised cover. Two devices: a 2 gang cover, or the 8371 when both are duplex receptacles. Then measure the finish. The raise should equal the thickness of the drywall, plaster or panelling in front of the box: 1/2" for standard drywall, 3/8" or 7/8" when the finish is thinner or thicker.
Material matters too. The ARANI covers in this category are steel: they are rigid, resist impact in garages and utility rooms, and keep the bonding path continuous between a metal box and the device yoke. On a metal box, a steel cover is the natural match. When a box is installed outdoors or in concrete, use the accessory designed for that location, such as the concrete pour mounting boxes, rather than an indoor cover.
Finish the opening with the right electrical outlets, light switches and Decora wall plates. The boxes themselves are in the octagonal boxes and gang boxes categories.
In homes, raised covers on square boxes are common in garages, workshops and unfinished basements, where receptacles sit on exposed boxes. Blank covers close junctions in attics and ceilings. Outside, concrete pour boxes prepare in-ground lights for driveways, walkways and patios; see the LED landscape lighting guide and the driveway lighting ideas. In commercial work, 4 11/16" boxes with matching covers are the usual choice where many conductors meet.
They fit two different square box sizes. The 4 11/16" box offers more room for conductors, and its covers, such as the 72C1 and the 72C13, are wider. A 4" cover will not close a 4 11/16" box, so check the box size before you order a batch of covers for a project.
Choose a raise that equals the finish thickness. A 1/2" raise, like the 52C13 or 52C17, suits standard drywall. The 52C15 with a 7/8" raise is for thicker finishes.
Yes. The 54C1 closes an octagonal box that only holds splices. The box must stay accessible after the work is finished.
It is a 2 gang 4" cover with a 3/8" raise and two duplex openings, so two standard receptacles mount side by side on one square box.
No. The RD32, RD33 and RD34 mounting boxes with top plates are accessories installed before the pour. The matching in-concrete LED light is a separate product.
It closes a junction box where an LED strip installation connects to household wiring, so the splice stays enclosed and the finish looks clean.
Browse all box covers and plates, or see the full range of electrical boxes to match each cover with its box.