Single and Multi-Gang Boxes

Gang Boxes

Gang boxes are the electrical boxes that sit behind switches, receptacles, dimmers and smart controls. This category groups single-gang and multi-gang device boxes from 1 to 4 gangs: airtight and non-airtight plastic boxes, gangable boxes with ears, bubble boxes with extra volume, deep boxes with positioning tabs, steel stud mount boxes for armoured cable and old work rework boxes for renovations. Every model is made by ARANI, and the product sheets list cUL or CSA approval.

The page is written for electricians, contractors and homeowners planning a rough-in. Whether you are wiring a new house, finishing a basement or adding a switch in an existing wall, the right gang box depends on four things: the number of devices, the volume you need for conductors, the cable type and the wall assembly. The sections below explain each choice with the real capacities of the boxes listed here.

Types of gang boxes

Airtight and non-airtight plastic boxes

The SLH series covers 1, 2, 3 and 4 gangs in thermoplastic. The airtight versions carry an "A" suffix: the SLH-1A 1 gang airtight box (18 cu. in.), the SLH-2A at 33 cu. in., the SLH-3A at 48 cu. in. and the SLH-5A 4 gang airtight box (67 cu. in.). An airtight box keeps the air barrier continuous where a device crosses an exterior wall or a ceiling under the attic, which limits drafts and condensation in the wall cavity. The non-airtight SLH-1, SLH-2, SLH-3 and SLH-5 offer the same volumes for interior partitions where no air barrier is involved.

Gangable boxes with ears or clamps

Gangable boxes have a removable side, so two or more boxes can be joined to build a multi-device opening. The 1100-L (8 cu. in.), 1102-L (10 cu. in.), 1104-L (12.5 cu. in.) and 1004-L deep box (15 cu. in.) come with ears and an NMD clamp. The 1104-LH and 1004-LH skip the ears, the 1104-K uses knockouts instead of clamps, and the 1104-LA and 1104-LHA take armoured cable.

Bubble boxes and deep boxes

A bubble box has a domed back that adds wiring room without a deeper stud. The 1304-LH offers 15 cu. in. and the 3104-LH gangable bubble box (16 cu. in.) comes with NMD clamps, while the 3104-LHA takes armoured cable. For a deeper rough-in, the 2304-LH family uses a 2 1/2" depth with positioning tabs and clamps, in 1, 2, 3 and 4 gang formats, sold in packs of 50, 20, 20 and 10 boxes.

Stud mount and device boxes

Stud mount boxes fasten to the framing with a bracket. The 2104-LSSAX series takes armoured cable and grows from 1 gang (12.5 cu. in.) to 2 gangs (25 cu. in.), 3 gangs (37.5 cu. in.) and 4 gangs (50 cu. in.). The 3104-LSSAX, 3104-LSSAX-1 for double drywall and 3104-KSSX with knockouts are bubble versions at 16 cu. in. The 2104-LLE series offers the same 12.5, 25, 37.5 and 50 cu. in. volumes with NMD clamps. For renovation, the 777-LRB 1 gang rework box (11 cu. in.) anchors to the drywall with retention tabs when no stud is reachable.

Specs to check before you order

A gang box is simple, but four specifications decide whether it passes inspection and whether the device fits without forcing.

FormatPlastic SLHDevice box 2104-LLEStud mount 2104-LSSAX
1 gang18 cu. in.12.5 cu. in.12.5 cu. in.
2 gang33 cu. in.25 cu. in.25 cu. in.
3 gang48 cu. in.37.5 cu. in.37.5 cu. in.
4 gang67 cu. in.50 cu. in.50 cu. in.
  • Volume (cubic inches): the Canadian Electrical Code limits how many conductors, connectors and devices a box can hold. Dimmers, smart switches and pigtails take room, so size up when in doubt.
  • Cable entry: NMD clamps for non-metallic sheathed cable, armoured cable clamps for BX, AC90 or similar armoured cable, or knockouts when you use separate connectors or conduit.
  • Air sealing: airtight boxes for exterior walls and insulated ceilings, non-airtight boxes for interior partitions.
  • Approval: the product sheets list cUL or CSA approval, which inspectors look for on every box.

How to choose the right gang box

Start with the devices. One switch or one receptacle needs a 1 gang box; a bank of switches beside a door often needs 3 or 4 gangs. Gangable boxes let you build the opening on site, while a one-piece multi-gang box keeps the faceplate perfectly aligned. Pair the opening with the right light switches, electrical outlets and Decora wall plates.

Then count conductors. A plain switch leg fits in a small box, but an LED dimmer, a 3-way switch or a smart switch with a neutral adds bulk. Our LED dimmer switch guide and the smart light switches guide explain which devices need a neutral and more room. A bubble box or a deep 2 1/2" box solves most crowding problems.

Finally, match the cable and the framing. NMD cable goes with NMD clamps; armoured cable goes with the LSSAX or LA models. Steel stud framing and double drywall have their own models, and old work calls for a rework box.

Installation and layout tips

  • Set the box depth to the finished wall: positioning tabs on the 2304-LH series make this repeatable on every stud.
  • On an exterior wall, seal the airtight box to the vapour barrier so the barrier stays continuous.
  • Keep switch heights consistent across the house, and align multi-gang boxes with door trims.
  • When the box ends up recessed behind thick finishes, a raised cover from the box covers and plates category brings the device plane forward.
  • Ceiling fixtures and junctions belong in octagonal boxes, not in gang boxes.

For a whole-house plan, the new construction LED lighting plan shows where switches and controls usually go, room by room.

Residential and commercial uses

In homes, 1 and 2 gang airtight boxes handle most switches and receptacles on exterior walls, while 3 and 4 gang boxes group the controls for pot lights, under cabinet lighting and fans at a kitchen entrance. In basements and condos, rework boxes and gangable boxes adapt to existing walls. In light commercial work, steel stud mount boxes with armoured cable clamps are the usual choice for offices and retail fit-outs.

FAQ

What does "gang" mean on an electrical box?

A gang is one device position. A 1 gang box holds one switch or receptacle, a 2 gang box holds two side by side, and so on up to 4 gangs in this category.

When do I need an airtight electrical box?

Use an airtight box wherever a device crosses the air barrier: exterior walls and ceilings below an unheated attic. Interior partitions can use non-airtight boxes such as the SLH-1 or SLH-2.

How many cubic inches do I need for a dimmer or a smart switch?

It depends on the number of conductors and connectors. Smart switches and dimmers are bulky, so choose a deep, bubble or larger box, for example 16 cu. in. instead of 12.5 cu. in. for a single device, and confirm the fill with the Canadian Electrical Code.

What is the difference between NMD clamps and armoured cable clamps?

NMD clamps grip non-metallic sheathed cable, the usual wiring in Canadian homes. Armoured cable clamps hold BX or AC90 armoured cable and keep the bonding path through the metal box.

Can I join gangable boxes to make a 3 gang opening?

Yes. Remove the side of each gangable box and join them. For a cleaner alignment, a one-piece 3 gang box such as the SLH-3A or the 2104-LLE3 is faster.

Which box do I use in an existing finished wall?

Use an old work rework box such as the 777-LRB. Its tabs clamp onto the drywall, so no stud access is needed.

Browse all gang boxes, or see the full range of electrical boxes to complete your rough-in with matching covers and octagonal boxes.

Filter Products