If you've ever wished a fixture could just know when it's dark out, the JL-200 photocell receptacle is the component that makes that possible. It's designed specifically
for fixtures that are not equipped with a twist-lock receptacle to accommodate a photocell, giving you a clean, factory-style way to add daylight-sensing control after the fact rather than replacing the whole fixture.
Construction and installationThe receptacle mounts directly onto the fixture using the included gasket and screws, with a keyed north-arrow alignment that ensures it only goes on correctly. Installation starts by disconnecting power and removing the fixture's blanking cover, then feeding the receptacle wires through into the driver compartment and securing the unit for a watertight connection. Wiring follows a straightforward diagram covering line, neutral, ground, and surge suppressor connections — and for luminaires with two LED drivers, the second driver simply connects into the same points as the first. Once wired, the photocell (sold separately) is installed by pushing it down and twisting clockwise into the keyed socket, which only accepts the correct orientation.
Compatibility and accessoriesThe JL-200 is designed to pair with the
JL-205LV photocell or the
JL-207E photocell, both sold separately. If the photocell function isn't needed right away — or is later removed — the
JL-208 shorting cap can be installed instead to keep the circuit closed, so the fixture keeps operating normally until you're ready to add automated photocontrol. This modular approach means a single fixture platform can be configured as manually wired, automatically controlled, or quickly converted between the two.
Technical specificationsOrder Code: JL-200
Applicable Voltage: 0-480V
Rated Frequency: 50/60Hz
Suggested Loading: AWG#18: 10Amp; AWG#14: 15Amp
Operating temp: -40℃ to 70℃
Related Humidity: 99%
Approx. Weight: 80g
Leads: 6" min
Safety and documentationInstallation and maintenance must be performed by a qualified electrician in accordance with the National Electrical Code and applicable local codes, with proper grounding carefully observed as outlined in the installation instructions. Incorrect installation that results in water ingress or luminaire damage may void the manufacturer's warranty, so follow the gasket and sealing steps closely. Full details — including the wiring diagram, mounting sequence, and warnings — are available in the installation PDF (JL-200 - Installation Guide) and the technical PDF (JL-200 - Spec Sheet EN), both available in the documentation section of this page.