Looking for the technical details behind the CSC LED
HB01DMS-B motion sensor? This page covers how it works, how to install it, and exactly which settings you can configure to match your space.
Detection technologyThe HB01DMS-B uses dual PD (passive infrared + photodiode) technology combined with a microwave frequency of
5.8GHz±75MHz and microwave power under
0.5mW, allowing it to distinguish artificial light from natural daylight once installed. This enables the Lux ON/OFF function: the fixture turns on automatically when ambient brightness drops below your preset Daylight Threshold, dims to standby when no motion is detected after the Hold Time expires, and shuts off completely once ambient light exceeds the preset lux level — provided the Stand-by Period is set to +∞, the Stand-by Dimming Level is set to 10%, 20%, 30% or 50%, and a Daylight Threshold of 10, 30, 50 or 100 Lux is selected.
Installation and wiringThe sensor connects to the LED driver via three control wires: Pink (+12V), Purple (DIM+), and Gray (GND/DIM-), delivering a
0-10V dimming output directly to compatible high bay drivers. It is designed to seat into the luminaire's receptacle without extensive rewiring or additional junction boxes — simply remove the plastic protector covering the sensor's pins before installation and ensure full contact with the fixture's circular receptacle. Mounting height is rated up to
15m ceiling mounted, with a detection range of
ø15m ceiling mounted or max 20m wall mounted, and a detection angle of
30-150°.
Programming with the MS04-RC remoteConfiguration requires the
MS04-RC remote control, ordered separately, which is also compatible with the MS04-MW-TW-DC, HB01DMS-C, and MS01-PIR-TW-DC sensors. Using the remote, you can set Brightness (70%, 80%, 90%, 100%), Hold Time (10s, 1min, 10min, 30min), Sensitivity (25%, 50%, 75%, 100%), Stand-by Time (1min, 30min, 60min, +∞), Stand-by Dimming Level (10%, 20%, 30%, 50%) and the Daylight Threshold. Settings are saved by pressing SEND while pointing the remote at the installed, powered sensor — the luminaire flickers ON/OFF to confirm. A TEST button and RESET-to-default function are also available, and one remote can program an unlimited number of sensors with no pairing process required.
Technical specificationsModel: HB01DMS-B
Universal Input Voltage: 12±2V DC
Operating Current: 30mA
Output: DIM 0-10V
Stand-by Power: < 0.5W
Brightness: 70%, 80%, 90%, 100%
Sensitivity: 25%, 50%, 75%, 100%
Hold Time: 10s, 1 min, 10 mins, 30 mins
Daylight Threshold: 10Lux, 30Lux, 50Lux, 100Lux
Stand-by Period: 1 min, 30 mins, 60 mins, +∞
Stand-by Dimming Level: 10%, 20%, 30%, 50%
Microwave Frequency: 5.8GHz±75MHz
Microwave Power: <0.5mW
Detection Angle: 30-150°
Mounting Height: Max. 15m (ceiling mounted)
Detection Range: ø15m (ceiling mounted), Max. 20m (wall mounted)
Operating Temperature: -25°C to 60°C
IP Rating: IP65
Certification: cUL
Full installation details, wiring diagrams and the MS04-RC programming manual are available in the Documentation tab via the HB01DMS-B Installation Guide PDF. Suited for garages, workshops, warehouses and any space using LHB2 or LHB03 high bay fixtures, this sensor delivers hands-off, energy-smart lighting control season after season.