RUNNING MAN 2 | STEEL | NO BAT | 1W | 6-24VDC OR 120-347V | V1
RUNNING MAN 2 | STEEL | NO BAT | 1W | 6-24VDC OR 120-347V | V1

EX-RM2-1W-DC-V1 – RUNNING MAN 2 | STEEL | NO BAT | 1W | 6-24VDC OR 120-347V | V1

SKU: EX-RM2-1W-DC-V1

Brand: ARANI

Looking for a dependable exit sign that won't let you down when it matters most? The ARANI Running Man 2 (SKU: EX-RM2-1W-DC-V1) is a steel, no-battery running man exit sign built for buildings that already run on a centralized emergency circuit or generator backup. Also known as a pictogram exit sign or illuminated exit sign, this double-sided, surface/wall-mount unit is the workhorse fixture commercial electricians specify for offices, retail stores, warehouses, schools, and multi-unit residential buildings where code-mandated egress lighting is non-negotiable.

This version runs on a low 1W LED load, with a flexible 6-24VDC or 120-347V input range that lets a single SKU cover both low-voltage emergency systems and standard-to-high line voltage circuits — including the 347V service common in Canadian commercial buildings. The crisp 5000K colour temperature keeps the pictogram sharp and easy to spot from a distance, while the rugged steel enclosure is rated IP40 and suitable for damp locations, so it holds up in stairwells, loading docks, and other less-than-pristine environments. With an LED lifetime of 50,000 hours and a 5-year warranty, you're not going to be back on a ladder changing lamps every year. Interchangeable stencils (arrow left, arrow right, or no arrow) and double-sided printing mean one fixture adapts to almost any corridor layout.

Because this is the no battery version, it's the right call when your building's emergency lighting is already fed by a central inverter, generator, or dedicated low-voltage DC emergency circuit — simplifying wiring and avoiding redundant batteries throughout the floor plan. If you need a self-contained unit with its own backup power instead, the Running Man 2 with battery backup is the direct equivalent, and for larger combo applications with built-in emergency heads, check out the Combo Running Man sign with 2-head battery backup. Whether you're outfitting a new build or retrofitting an older Canadian property to meet current code, the Running Man 2 delivers safe, reliable, low-maintenance egress lighting. Order yours today and keep your exits clearly marked, day and night.

86.97$


Spec sheet (PDF)

Supplier availability: In stock (+100)

Description and specifications – EX-RM2-1W-DC-V1

Reliable egress signage isn't just a nice-to-have — it's a code requirement, and the ARANI Running Man 2 (EX-RM2-1W-DC-V1) is engineered to deliver it without fuss. This steel pictogram sign is built for facilities that prefer a centralized emergency power strategy rather than individual battery backups in every sign, making it a popular choice for larger commercial and institutional buildings across Canada.

Light quality and construction
The sign uses an efficient LED module running at just 1W, producing a clean, uniform 5000K daylight-white glow across the running man pictogram — easy to read even in smoky or low-visibility emergency conditions. The steel housing offers real durability over plastic alternatives, and the fixture carries an IP40 rating, making it suitable for damp locations such as stairwells, parking garages, and loading areas. Measuring 192mm x 192mm x 54mm with a 120mm stencil viewing area, it mounts flush to ceilings or walls without dominating the space.

Electrical and installation details
This model accepts 6-24VDC or 120-347V input, giving installers the flexibility to tie into low-voltage emergency DC circuits or standard AC line voltage up to 347V — a real advantage in Canadian commercial installations where 347V lighting circuits are common. Operating temperature range is 4°C to 32°C, and like all ARANI emergency signage, it must be installed indoors by a licensed electrician, properly grounded, and wired according to national and local electrical codes. Full step-by-step wiring diagrams and mounting instructions (ceiling and wall configurations) are available in the installation guide included in the Documentation tab.

Compatibility and included accessories
The sign ships with interchangeable stencils — a running man with arrow (left or right facing) and a running man without arrow — printed double-sided for two-way visibility in corridors and open areas. Since this is the no-battery configuration, it's designed to be powered from a central emergency circuit rather than operate independently; for a self-contained alternative with its own 6V/6Ah battery, see the Running Man 2 with battery backup. For combination applications requiring both exit signage and emergency head illumination in one fixture, the Combo Running Man sign and its black finish version offer built-in battery backup and dual emergency heads; both accept the 4' plug-in power cord for emergency lights as an optional accessory.

Technical specifications
SKU: EX-RM2-1W-DC-V1
Material: Steel
Input Voltage: 6-24VDC or 120-347V
Rated Power: 1W
Colour Temperature: 5000K
IP Rating: IP40 — suitable for damp locations
Dimensions: 192mm x 192mm x 54mm
Stencil viewing area: 120mm
Operating Temperature: 4°C to 32°C
LED Lifetime: 50,000 hours
Warranty: 5 Years