Direct 347V connectionCommercial and institutional buildings across Canada often light their spaces on
347V circuits. This HV version of the 3 ft LBI connects to them directly, with its driver built into the sleek protective housing, 31.3" long and only 1.2" high. No transformer, no remote driver box: fewer components to install and fewer points of failure. Mounting clip options with integrated
rare-earth magnets make placement quick in all fixture styles, high-bay pendant chain options are available, and a 45° bracket projects light more efficiently out of a cove.
Output and colour, set on siteFlexWatt and
FlexColor technology offer 9 SKUs in 1 unit. Position 1, 2 or 3 gives 10W (1335 lumens), 12W (1648 lumens) or 15W (1961 lumens), measured at 3500K, and the standard colour switch (WC) selects 3500K neutral, 4000K natural or 5000K cool. Install it at its default setting or tailor each zone, and larger orders can be factory pre-set to save labour. The CRI of 80+ and 120° beam angle wash walls, ceilings and work surfaces with comfortable, natural light.
Linking, dimming and controlsThe bars
daisy-chain for fast installation. Power enters through the
3 ft incoming power kit RP-LBI-G1-IP-3F-DIM (incoming power cable or pigtail, service disconnect and grommet), and units connect with seamless connectors or linking cables. Linking quantities depend on voltage, so check the manufacturer's linking chart for a 347V run. Pass-through
0-10V dimming and an auxiliary 12V output let the run dim as a group. Optional in-line occupancy and daylight sensors and Bluetooth mesh control nodes link directly to the bars with no extra wiring; sensors cannot be installed behind a lens. An optional remote emergency battery backup is offered.
Technical specificationsLength: 3 ft (31.3" x 1.2")
Wattage: 10W / 12W / 15W (default 10W)
Lumens at 3500K: 1335 / 1648 / 1961
Colour temperature: 3500K / 4000K / 5000K (default 4000K)
Voltage: 347V
Efficacy: up to 146 lm/W (light engine)
CRI: 80+
Beam angle: 120°
Power factor / THD: above 0.9 / under 20%
Operating temperature: -13°F to 140°F
Location: dry and damp
Rated life: L70 over 100,000 hours
Listing: UL 1598 listed fixture
Applications and documentationUse it for
indirect cove lighting in school and hospital lobbies, for continuous lines in office corridors, or to replace fluorescent strips in mechanical rooms and plants wired at
347V. The spec sheet, with part number builder, control options and DLC information, is in the Documentation tab.